アカデミー記事
Comparison of Inherent FR and Chemical Finish Durability
T
著者: TRTex Editorial Team
公開日: 2026年6月22日 · 最終確認日: 2026年9月29日 · ⏱️ 2 分で読めます
Concepts of Inherent Flame Retardancy and Chemical Finish
Fire safety in contract textiles is ensured through technologies that retard the ignition behavior of fabric exposed to flame [1], [2].In this field, there are two primary approaches: 'Inherent FR' (inherently flame retardant) and 'chemical finish' [2], [3].
In inherent FR technology, flame retardancy is integrated at the molecular level into the polymer backbone during chemical polymerization or spinning stages [2], [3].
In phosphorus-modified polyester fibers (for example Trevira CS), which are among the most common representatives of this group, flame-retardant organic phosphorus monomers are bound to the polymer chain via covalent bonds [1], [3].
Kanecaron is also an inherent FR fiber [2].
Chemical Finish Coatings and Differences in Laundering Durability
In the chemical finish method, the FR chemical is applied to the fabric subsequently [3].Because non-durable finishes can be removed by water, these fabrics may lose their FR properties upon laundering [1], [3].
In inherent fibers, by contrast, flame retardancy is an intrinsic property of the fiber structure [2], [3].
Industrial 50 Laundering and Healthcare Sector Specifications
The HTM 05-03 Part C fire safety guidance published by the UK National Health Service (NHS) serves as the primary reference for curtain and fabric selection across healthcare campuses [1].The NHS guide recommends the BS 5867-2 Type B standard as the baseline performance tier for curtains deployed in hospitals and clinics [1].
Contrary to popular industry assumption, the 50-wash requirement is not mandatory across all hospital premises; Type C performance tested after 50 industrial washes is recommended solely for high-risk specialized zones [1].
Because hospital textiles are laundered at high temperatures, the FR performance of fabrics used in these settings must be durable to laundering [1].
T
TRTex Editorial Team
AIの支援により作成 · TRTex AI
本コンテンツはAIの支援により作成されています(EU AI法 2024/1689、第50条)。出典のある情報には出典へのリンクを付しています。誤りや不足している情報にお気づきの場合は、お問い合わせページからご連絡ください。
出典・引用
- NHS England — HTM 05-03 Part C (閲覧日: 2026-09-29) — england.nhs.uk ↗
- KANEKA Corporation (閲覧日: 2026-09-29) — modacrylic.com ↗
- Polymers (MDPI) (閲覧日: 2026-09-29) — mdpi.com ↗
- IMO — Resolution MSC.307(88), 2010 FTP Code (閲覧日: 2026-09-29) — wwwcdn.imo.org ↗
- IMO — Resolution MSC.307(88), 2010 FTP Code (閲覧日: 2026-09-29) — wwwcdn.imo.org ↗