ACADEMY ARTICLE

NFPA 701 (US) and European Fire Standards Differences

T
Author: TRTex Editorial Team
Published: 22 June 2026 · Last reviewed: 29 September 2026 · ⏱️ 2 min read
NFPA 701 (US) and European Fire Standards Differences

Fire Standards Distinction in Global Markets

In the US, NFPA 701 is required for curtains and similar hanging decorative materials [1].
A Class 1 certificate obtained in the EU does not substitute for NFPA 701 in the US [3].

NFPA 701 Test Methods and Acceptance Criteria

NFPA 701 includes two test methods [3].
Fabric weight and structural layer properties determine the selection of the test method [3].
Method 1 is applied to fabrics under 700 g/m² [3].
Method 2 is applied to heavier fabrics, vinyl-coated blackout fabrics and banners [3].
In the Method 1 test, 10 specimens measuring 150 x 400 mm are used [3].
To pass the test, flaming drip droplets falling to the floor of the test chamber must not burn for an average of more than 2 seconds [3].
T

TRTex Editorial Team

Prepared with AI assistance · TRTex AI

This content was prepared with AI assistance (EU AI Act 2024/1689, Article 50). Information with a source is given with a link to that source; if you notice incorrect or missing information, please write to us via the contact page.

SOURCES & CITATIONS
  1. International Code Council (IBC 2024, Bölüm 806.4) (accessed: 2026-09-29) — codes.iccsafe.org ↗
  2. British Columbia Fire Code 2018 (Madde 2.3.2.1) (accessed: 2026-09-29) — free.bcpublications.ca ↗
  3. Element Materials Technology (NFPA 701-2019 Test Method 1 Raporu) (accessed: 2026-09-29) — medias.pim.saintclairtextiles.com ↗
  4. NFPA (NFPA 701 First Revision Report) (accessed: 2026-09-29) — docinfofiles.nfpa.org ↗
  5. NFPA (NFPA 701 Belge Sayfası) (accessed: 2026-09-29) — nfpa.org ↗